PV20a / PV30a pellet burner
DK9902A1 www.pelltech.eu
Table 12 Status’ durations
7 Error messages and solutions
Table 13 Error messages on screen
Battery voltage is less than 12V with working feeder motor.
- If there was a power failure then just wait when it is charged.
- Replace battery ( 4.8.8).
Flame is not detected at ignition time.
- Igniter is out of order or fuse is blown. Usually fuse blows when igniter is broken or its
body is in short circuit. Replace igniter or fuse F4 (5.8.1 and 4.8.3).
Igniter’s resistance has increased with years. Normal resistance has to be 106…110 Ω.
- Replace igniter (5.8.1).
Flame sensor is dirty or is melt.
- Clean or replace sensor if needed (4.8.5).
Amount of pellets for igniting is too small.
- If error is frequent, increase amount of pellets PAR24.
Burner is turned OFF from main menu.
- To turn burner on hold OK button down 3 seconds or change in BURNER menu OFF to
ON
Feeder auger doesn’t rotate.
- Remove plastic hose and check is there any foreign object or very long pellet jammed
the feeder auger. Remove obstacle.
Fuel level sensor displays permanently existence of pellets in feeder’s tube.
- Level sensors are dirty or melt. Clean or replace sensors if needed (4.8.4).
Poor draught made sensors dirty.
- Check sensor, clean if needed. Improve draught.