PV20a / PV30a pellet burner
page 40/ 41
DK9902A1 www.pelltech.eu
PAR49
CLEANING TIME
Opening time of pneumo valve in cleaning cycle
1/2sec
3
0
10
3
0
10
PAR50
RELAY ERROR
ERR output function selection
1- relay NO
2 - relay NC
3 - Circulation pump control (accum. tank loading)
4 - reserv
5 - 230V solenoid valve control (pneumatic clean
version)
6 - turbulators control
1…6
6
1
6
6
1
6
PAR52
SMS COUNT
Selecting number of phones receiving alert SMS
0…5
0
0
5
0
0
5
PAR53
TEMP.TYPE
Determines temp. sensor plugged to TMP1
connector
0 - no sensor
1 - burners over temp. sensor
2 - external temp. sensor
0…2
1
1
2
1
1
2
PAR54
TEMP.LEVEL
Set-point value for temperature sensor plugged to
TMP1
°C
70
30
240
70
30
240
PAR55
TEMP.HYST
PAR54 maximum set point hysteresis
°C
5
2
10
5
2
10
PAR56
TURBUS CYCLE
Time between two cleaning cycles of turbulators
min
60
0
250
60
0
250
PAR57
TURBUS TIME
Lenght of turbulators cleaning cycle
sec
60
10
250
60
10
250
PAR58
BASE FREQUENCY
Grid frequency
Hz
50
45
63
50
45
63
PAR60
FLUE GAS TYPE
Not in use here
-
0
0
2
0
0
2
PAR61
DRAFT SET
Flue gas fan pre-set pressure set point
-Pa
8
0
250
8
0
250
PAR62
DRAFT ERROR
Draught error threshold value. When set = 0, no
draft error counted.
+Pa
10
0
20
10
0
20
PAR63
DRAFT BASE
Draught sensor calibration value
%
110
50
150
110
50
150
PAR66
OXYGEN TYPE
Type of oxygene sensor:
0 no sensor;
1 4..20mA=0..25%;
2 4..20mA=0..20%
0…2
0
0
1
0
0
1
PAR67
OXYGEN SET
Oxygen level setpoint
%
6
4
12
6
4
12
PAR70
HEAT UP TIME
Initial heat up time for burners with ceramic
burning chamber
min
0
0
60
0
0
60
PAR71
HEAT UP POWER
Initial heat up power for burners with ceramic
burning chamber
kW
3
1
10
3
1
10
PAR99
BURNER TYPE
Selecting model of burner. Software of wrongly
selected model works incorrectly
-
20b
20a
500
30b
20a
500
In order to restore factory /default settings select PAR99 and click OK, model of burner starts to blink,
click OK again.
11 Annex 4 List of languages
Table 15 List of languages
Language