Opening time of pneumo valve in cleaning cycle
ERR output function selection
1- relay NO
2 - relay NC
3 - Circulation pump control (accum. tank loading)
4 - reserv
5 - 230V solenoid valve control (pneumatic clean
version)
6 - turbulators control
Selecting number of phones receiving alert SMS
Determines temp. sensor plugged to TMP1
connector
0 - no sensor
1 - burners over temp. sensor
2 - external temp. sensor
Set-point value for temperature sensor plugged to
TMP1
PAR54 maximum set point hysteresis
Time between two cleaning cycles of turbulators
Lenght of turbulators cleaning cycle
Flue gas fan pre-set pressure set point
Draught error threshold value. When set = 0, no
draft error counted.
Draught sensor calibration value
Type of oxygene sensor:
0 no sensor;
1 4..20mA=0..25%;
2 4..20mA=0..20%
Initial heat up time for burners with ceramic
burning chamber
Initial heat up power for burners with ceramic
burning chamber
Selecting model of burner. Software of wrongly
selected model works incorrectly
In order to restore factory /default settings select PAR99 and click OK, model of burner starts to blink,
click OK again.
11 Annex 4 List of languages
Table 15 List of languages