1020 Mono Filler
1
PENKO Engineering B.V.
Your Partner for Fully Engineered Factory Solutions
Manual:
1020 Supplement Mono Filler Controller
Question and Answer IconNeed help?

Do you have a question about the PENKO 1020 Series and is the answer not in the manual?

PENKO 1020 Series Specifications

General IconGeneral
CategoryController
Power Supply115/230 VAC or 24 VDC
Operating Temperature-10°C to +40°C (14°F to 104°F)
CommunicationSerial: RS232/RS485
Input Voltage115/230 VAC or 24 VDC
Output CurrentNot specified in provided documents
Dimensions192 x 96 x 145 mm (7.56 x 3.78 x 5.71 inch)

Summary

1 Introduction

2 Indication of display

Options for Indication 2nd Screen

Explains how to switch between the two main display screens using the left or right key.

3 Configure and control

PENKO Configuration Software

Details on downloading and using PENKO Pi Mach II and PDI Client software for device configuration.

Device Configuration

Guides users through the device's menu structure and system setup for configuration.

Industrial Protocols

Overview of supported industrial protocols like Modbus, Profibus, EtherNet/IP, and ASCII for device configuration.

Totals

4 Parameters

Configuration Parameters

Detailed explanation of configuration parameters like Dosing, Weighing, Stability, H-Time, and K.E.B. time.

Recipe Parameters

Defines parameters related to recipes, including Setpoint, Turnover, Inflight, and tolerances.

Live Process Parameters

Describes parameters that can be read live using industrial protocol register functions.

5 Inputs and outputs

Inputs

Details the function and markers for Start/Stop, Accept tolerance, and Start dosing/release inputs.

Outputs

Describes the function of Coarse, Fine, Ready, Release/Alarm, and Dosing speed outputs.

6 Printer Ticket

7 Program basics

Out Dosing Procedure

Step-by-step explanation of the out-dosing process, including start, coarse/fine dosing, and tolerance checks.

In Dosing with Release Valve

Details the procedure for in-dosing when a release valve is used, noting Weighing parameter settings.

In Dosing without Release Valve

Describes the in-dosing process without a release valve, including Weighing parameter notes.

8 Default settings

Device Specific Setups

DAC Setup

Configuration of DAC settings, including indicator, min/max values, and mode.

Weigher Setup

Setup for weigher parameters such as unit label, step, decimal point, operation mode, and max load.

Stable Condition Setup

Configuration of stable condition parameters, including range and time settings.

Filter Digital Setup

Setup for digital filter settings, including cutoff frequency and frequency.