Page #24 background imageLoading...
Page #24 background image
1020 Mono Filler
24
Start the program with input 1 (start/stop)
o Dosing starts (tare will be taken depending on weigher mode)
o Output 1 (coarse) and output 2 (fine) turn on
o DAC is set to the coarse speed
Turnover value is reached
o Output 1 (coarse) turns off
o DAC is set to fine speed
Setpoint value is reached
o Output 2 (fine) turns off
o DAC is set to 0.00%
Dosed weight within tolerance?
o Output 3 (ready) turns on
o Dosing is complete
o A pulse on input 3 (start release) activates output 4 (release)
Dosed weight outside tolerance?
o Option to pulse input 2 (accept tolerance) to accept
o Output 3 (ready) turns on
o Dosing is complete
o A pulse on input 3 (start release) activates output 4 (release)
When weight is below value of Empty Level parameter a new dosing starts
Turn off input 1 (start/stop) to stop the program
7.3 In dosing without release valve
Dosing into the weigher without using a release valve:
Note the setting of the Weighing parameter:
If set to Net, a tare will be taken before every dosing
If set to Gross, tare will not be taken
Start the program with input 1 (start/stop)
A pulse on input 3 (start dosing) starts the dosing
o Dosing starts (tare will be taken depending on weigher mode)
o Output 1 (coarse) and output 2 (fine) turn on
o DAC is set to the coarse speed

Questions and Answers: