1020 Mono Filler
25
Turnover value is reached
o Output 1 (coarse) turns off
o DAC is set to fine speed
Setpoint value is reached
o Output 2 (fine) turns off
o DAC is set to 0.00%
Dosed weight within tolerance?
o Output 3 (ready) turns on
o Dosing is complete
Dosed weight outside tolerance?
o Option to pulse input 2 (accept tolerance) to accept
o Output 3 (ready) turns on
o Dosing is complete
A pulse on input 3 (start dosing) starts a new dosing
Turn off input 1 (start/stop) to stop the program