INDUSTRIAL HEAT TRACING SOLUTIONS
920 Series SSR Output Modules
Operating Temperature –40°F to 104°F (–40°C to 40°C)
SwitchRating • 30Aresistivecontinuous@277Vacmax.standard,
600 Vac max. optional, 1 PH, 50/60 Hz, 80 A 1 sec.
in-rush, 625 A 1cycle in-rush
• 60Aresistivecontinuous@600Vacmax.,1PH,50/60
Hz, 120 A 1 sec. in-rush, 1000 A 1 cycle in-rush
Input Drive Requirement 4-32 Vdc, 1500 Ω nominal input resistance
Environment Type 4X / IP66
920 Series Contactor Ratings
Operating Temperature –40°F to 104°F (–40°C to 40°C)
Contact Rating 30 A resistive continuous @ 600 Vac max. standard,
60 A maximum opt., 50/60Hz, 3 pole Coil Rating 120
or 208/240 or 277 Vac, 50/60 Hz, 109 VA in-rush,
10 VA sealed
920 Series Operator Console
Operating Temperature –40°F to 104°F (–40°C to 60°C)
Power Requirement +9 Vdc nominal, 500 ma maximum