38 6EM Thru 18GM - 1100 Vertical Turbine Pumps
SECTION 5 MAINTENANCE
Preventive Maintenance
To assure satisfactory operation of the
pump, scheduled inspection and periodic
maintenance are required. We suggest an
inspection and maintenance log be kept and
the inspector immediately report any
problems.
This Layne/Verti-Line model 1100 vertical
turbine pump is supplied with product
lubricated column and bowl bearings. The
suction bell bearing is grease packed at the
factory. It is not necessary to re-lubricate
this bearing except when the pump is to be
torn down for maintenance and the bowl
assembly is to be disassembled.
A guide for preventive maintenance for
normal applications is given below. Unusual
applications with abnormal heat, moisture,
dust, etc., may require more frequent
inspection and service.
Item Action Required
Seal Box Inspect every 150 hrs of
operation for excessive
leakage. Adjust or replace
packing as required.
Repair or replace
Mechanical Seal
Driver
Bearings
Lubricate according to
instructions given in the
driver O&M in Section 8 of
this manual.
Pump
Alignment
Check for changes
annually. Correct as
required.
Noise Level Check for changes
annually. Correct as
required.
Pump
Vibration
Check for changes
annually. Correct as
required.
Grease Recommendation
The following lubricants are recommended
for both potable and non-potable pumping
systems:
Non-Potable System
Manufacturer Type
Generic N.L.G.I. #2 Lithium base
multi-purpose grease
with a mineral oil
viscosity of 750-1050
SSU at 100
°
F and 75-82
SSU at 210
°
F
Atlantic
Richfield
ARCO MP #2
Gulf Gulfcrown #2
Sinclair Litholine MP #2
Texaco Marfak #958
Potable Water System
Generic N.L.G.I. #2 meeting FDA
Regulation 178.3570 and
has USDA Type H-1 and
FDA approvals for
incidental food contact
Chevron FM Grade 2
Ideal FG #2
Keystone Nevastone HT/AW2
Lubriplate FGL-2
Mobile FM Grade 2
Mechanical Seal
The pump furnished on this order is
equipped with a mechanical seal. Refer to
the Mechanical Seal section of this manual
for instructions regarding maintenance of
the seal.
Packing Adjustment
Generally, packed box pumps should be
checked every 150 hours of operation and
the glands should be readjusted if
necessary. Initial adjustment is accomp-
lished by tightening the gland nuts finger
tight.