Loading...
Rev. C 4/2017 ETi 400 High Efficiency Pool and Spa Heater Installation and User’s Guide
39
ELECTRICAL CONNECTIONS
(CONTINUED)
Panel latch lock
Figure 31.
Section 2: Installation Instructions
120 VAC
(BLUE)
220 VAC
(RED)
Fireman Switch Board
240 VAC Wiring
Connect the RED PLUG (240 VAC) into the 12-pin plug located on the electrical panel, see Figure 30).
Connect the L1 to the BLACK WIRE in the heater and the other L2 to the RED WIRE at the heater.
Connect the GROUND WIRE to the GREEN WIRE in the heater.
120 VAC Wiring
Connect the BLUE PLUG (120 VAC) into the 12-pin plug located on the electrical panel, see Figure 30).
Connect the L1 to the BLACK WIRE in the heater.
Connect the NEUTRAL WIRE to the RED WIRE in the heater.
Connect the GROUND WIRE to the GREEN WIRE in the heater.
CAUTION! The 120 VAC (Blue plug)
voltage selector is NOT interchangable
with the MasterTemp
®
or StaRite
®
Heater voltage selector (Black plug)
Figure 32.