Gear
1-3/8” Male 1-3/8” Female Reduction Hydraulic
Splined PTO 1” Solid Shaft Splined PTO Units for Gas Motor Mounting
Shaft W/Keyway Coupler Engine Drive Flange Kit
2
Control Max. Max. Pump
Unit Model GPM PSI Model
9910-KIT 1990 6 290 D252
9910-GR40 11 580 D303/D403
9910-GS40GI 21 580 D50 & D30
9910-RM40 24 580 D503
General Safety Information
Control Units:
Control units are available for easy flow and pressure control
of your sprayer system. These units include a manual dump
valve and adjustable pressure relief valve to control pressure,
a liquid-filled pressure gauge to monitor pressure, and shut-off
valves to control flow. Control unit GR40 and GS40GI can be
remote mounted with kit no. 9910-KIT1741. Refer to the adjoin-
ing chart to select the proper control unit for your pump.
9910-D503 9910-KIT2200 9910-KIT2202 9910-KIT2204 9910-KIT1642 for 8 hp, or 9910-KIT 1640 for 5 hp 9910-HYD5312 8000-0056
9910-D252 N/A 3/4” Solid Shaft. Std. N/A Order gear reduced models N/A
9910-D303/403 9910-KIT2200 9910-KIT2202 9910-KIT1704 9910-KIT1640 for 5 hp 9910-HYD5312 8000-0056
9910-D30 9910-KIT1702 9910-KIT1703 9910-KIT1704 9910-KIT1640 for 5 hp 9910-HYD5312 8000-0056
9910-D50 9910-KIT1706 9910-KIT1707 9910-KIT1704 9910-KIT1642 for 8 hp, or 9910-KIT 1640 for 5 hp 9910-HYD5312
Pump
Model
Notes are used to notify of installation, operation, or
maintenance information that is important but not
safety related.
Caution is used to indicate the presence of a haz-
ard, which will or can cause minor injury or property
damage if the notice is ignored.
Warning denotes that a potential hazard exists and
indicates procedures that must be followed exactly
to either eliminate or reduce the hazard, and to avoid
serious personal injury, or prevent future safety
problems with the product.
Danger is used to indicate the presence of a hazard
that will result in severe personal injury, death, or
property damage if the notice is ignored.
• Do not pump flammable or explosive fluids
such as gasoline, fuel oil, kerosene, etc. Do not
use in explosive atmospheres. Do not pump
asphalt sealer, roofing compounds, concrete
sealers, or any two-step curing products. The
pump should only be used with liquids compat-
ible with the pump materials. Failure to follow
this notice can result in severe personal injury
and/or property damage and will void the prod-
uct warranty.
• Never use your hand to check the condition
of hydraulic lines or hoses. If hydraulic fluid
penetrates the skin, get medical attention imme-
diately. Failure to get proper medical attention
may result in loss of limb or life. The safest way
to check hydraulic lines is by holding a piece of
cardboard next to the hydraulic line or hose.
• The sound pressure level of the pump may
exceed 80dBA. Observe all safety precautions
when operating the pump within close proximity
for extended periods by wearing hearing pro-
tectors. Extended exposure to elevated sound
levels will result in permanent loss of hearing
acuteness, tinnitus, tiredness, stress, and other
effects such as loss of balance and awareness.
• Verify that pump shaft rotates freely prior to
engaging the pump drive.
Drive Options:
Order the appropriate shaft adapter kit or gear reduction unit for the
drive option requirements. Refer to the adjoining chart for proper
selection. For proper installation, refer to pages 4 through 8.
Hypro
Gearbox