pentair.com
INSTALLATION AND
OPERATION MANUAL
CLOSE-COUPLED AC MOTOR-DRIVEN
& PEDESTAL MOUNT CENTRIFUGAL PUMPS
9940-9750NRL
9940-9751NRL
L-0350C Rev. C (12-09-19)

Questions and Answers

  • M
    mitchellheidiJul 28, 2025
    How to fix a Pentair Water Pump that will not prime?
    • R
      Renee HughesJul 28, 2025
      If your Pentair Water Pump won't prime or retain prime after starting, it could be due to an air leak in the suction line, which would need repair or replacement. Another potential cause is a clogged foot valve or strainer, which should be cleaned or replaced.
  • M
    Michael SimsAug 1, 2025
    Why is the flow rate low on my Pentair HYPRO 9700 Water Pump?
    • C
      Cynthia MercerAug 1, 2025
      A low flow rate in your Pentair Water Pump can stem from several issues. It could be due to an incorrect speed setting, so check the drive. The piping might be fouled or damaged, requiring cleaning or replacement. A clogged or worn impeller can also restrict flow, so inspect and clean or replace it as needed. Additionally, the discharge line might be restricted or undersized, in which case you should flush out the piping or replace it. Finally, high discharge pressure could be the culprit, so check and reduce it if necessary.
  • M
    Miranda LoganAug 7, 2025
    What to do if my Pentair Water Pump runs but there is no fluid?
    • A
      Amanda GomezAug 7, 2025
      If your Pentair Water Pump runs but isn't pumping fluid, several factors could be at play. First, check for faulty suction piping and replace if necessary. The pump might be too far from the fluid source, requiring relocation. Ensure the gate valve is open. A clogged strainer or fouled foot valve can also prevent fluid flow, so clean or replace them. Lastly, the discharge height or suction lift might be too great; lower the height or the pump accordingly.
  • C
    collinskatieAug 11, 2025
    What to do if Pentair HYPRO 9700 Water Pump starts and stops pumping?
    • T
      Todd MosleyAug 11, 2025
      If your Pentair Water Pump starts and stops pumping, the issue might be due to a fouled impeller, which needs cleaning. Alternatively, it could be a faulty mechanical seal requiring replacement, a leak in the suction line needing repair, or a leak in the foot valve, which should be repaired or replaced.
  • A
    Angel VelasquezAug 17, 2025
    Why is liquid dripping from the shaft of my Pentair HYPRO 9700?
    • D
      Denise VillaAug 17, 2025
      If liquid drips from where the shaft enters the pump casing of your Pentair Water Pump when it's full, it's likely due to a damaged mechanical seal. You will need to replace it.
  • T
    Taylor FlynnAug 22, 2025
    How to reduce excessive noise from my Pentair HYPRO 9700?
    • L
      Leslie ElliottAug 22, 2025
      Excessive noise from your Pentair Water Pump during operation can be caused by several factors. First, ensure the pump is securely fastened to a firm foundation. Next, check that the piping is properly supported to relieve any strain on the pump assembly; make necessary adjustments. A restricted suction line can also cause noise, so clean or correct it. Finally, cavitation may be occurring; try reducing the speed, increasing the inlet size, or using a thinner material.

Summary

Description

General Safety Information

Troubleshooting

Drive Source Installation

Belt;Pulley Drive Installation

Details on mounting belts and pulleys for pump drive configuration.

Direct Drive - Flexible Coupling

Instructions for installing pumps with flexible couplings.

Electrical Hook-up

Installation

Performance for 9700 Series Pumps

Repair Instructions

Disassembly

Step-by-step guide for disassembling the pump components.

Pump End Assembly

Instructions for correctly reassembling the pump end.

Seal Recommendation

Direct Plumbing to City Water

Guidance on using city water for pump seal flushing.

Recirculation of the Solution Pumped

Method for flushing pump seals using the pumped liquid.

Hazardous Substance Alert

Limited Warranty on Hypro;Shurflo Agricultural Pumps & Accessories

Return Procedures

Steps for returning products for service or warranty consideration.

Pentair HYPRO 9700 Series Specifications

General IconGeneral
BrandPentair
ModelHYPRO 9700 Series
CategoryWater Pump
LanguageEnglish

Related product manuals