-5-
Installation
1. Position the pump as near as possible to the source being
pumped. A ooded suction situation is preferred. The pump
is not self-priming, therefore, if the uid level is below the
pump, a foot valve must be installed and the pump primed
prior to start-up. (See the gure above.)
2. Mount the motor base to a secure, immobile foundation.
3. Use only plastic ttings on both the intake and discharge
ports. Seal the pipe connections with teon tape. These
ttings should be self-supported and in neutral alignment
with each port. (i.e. Fittings must not be forced into align-
ment which may cause premature line failure or damage
to the pump volute.)
4. Never choke the intake. As much as possible, keep both
input and discharge lines free of elbows and valves . Al-
ways use the pipe of adequate diameter. This will reduce
friction losses and maximize output.
5. The pump is non-self-priming! The pump must not be
run dry! Hypro recommends a ooded suction. If this is
not possible, use a foot valve and prime the pump. (See
the gure above.)
Performance for 9700 Series Pumps
5 PSI 10 PSI 15 PSI 20 PSI 25 PSI 30 PSI Shut Off
Model GPM AMPS GPM AMPS GPM AMPS GPM AMPS GPM AMPS GPM AMPS PSI
9751 44 7.9 39 8 32 8.3 25 8.5 15 8.5 2 8.4 31
9753 88 14.1 82 14 74 14 66 14.4 55 14.4 37 13.6 35
10 PSI 15 PSI 20 PSI 25 PSI 30 PSI 35 PSI Shut Off
Speed GPM HP GPM HP GPM HP GPM HP GPM HP GPM HP PSI
3000 102 1.5 88 1.4 72 1.4 38 1 27
3450 126 2.4 114 2.4 101 2.2 86 2.2 64 1.9 14 1.4 36
3600 132 2.7 119 2.6 107 2.5 97 2.5 80 2.3 52 2 39
9940-9750 Pedestal Mount Centrifugal Pump
9940-9751 and 9940-9753 Close-Coupled Noryl Centrifugal Pumps