EasyManua.ls Logo

Pentair HYPRO 9700 Series - Description; General Safety Information

Pentair HYPRO 9700 Series
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-2-
Description
Hypro's 9700 series pumps are specically designed for bulk
transfer of fertilizer and agricultural chemicals. The pumps have
centrifugal force impellers for quiet, efcient pumping action.
The 9700 centrifugals feature Noryl housings, which provide a
wide range of corrosion resistance. The close-coupled models
are offered with 3/4 and 1 1/2 horsepower 115/208-230 volt
AC motors. The pedestal mount model is equipped with a
5/8" solid shaft.
General Safety Information
SERIES 9940-9751NRL
Max. Flow Rate: ...................... 132 gpm
Max. Pressure: ............................ 35 psi
Max. Speed:............................ 3600 rpm
Shaft: .......................................5/8" solid
Ports: ............................ 1-1/2" NPT inlet
1-1/2" NPT outlet
Max. Flow Rate: ....................... 44 gpm
Max. Pressure: .............................30 psi
Max. Speed: ............................ 3450 rpm
Motor: ............ 3/4 hp, 115/208-230V AC
Ports: ............................ 1-1/2" NPT inlet
1-1/2" NPT outlet
Max. Flow Rate: ........................ 88 gpm
Max. Pressure: .............................30 psi
Max. Speed:............................ 3450 rpm
Motor: ........ 1-1/2 hp, 115/208-230V AC
Ports: ............................ 1-1/2" NPT inlet
1-1/2" NPT outlet
SERIES 9940-9753NRL
Noryl Close-Coupled AC
Motor-Driven Centrifugal Pump
Noryl Close-Coupled AC
Motor-Driven Centrifugal Pump
Noryl Pedestal-Mount
Centrifugal Pump
SERIES 9940-9750NRL
WARNING: DO NOT pump ammable or explosive uids such
as gasoline, fuel oil, kerosene, etc. DO NOT use in explosive
atmospheres. The pump should be used only with liquids
compatible with the pump component materials. Failure to
follow this warning can result in personal injury and/or property
damage and will void the product warranty.
1. When wiring the motor, follow all local electrical and safety
codes as well as the National Electrical Code (NEC) and
the Occupational Safety and Health Act (OSHA).
2. Always disconnect the power source before performing
any work on or near the motor or its connected load. If the
power disconnect point is out-of sight, lock it in the open
position and tag it to prevent unexpected application of
power. Failure to do so could result in electrical shock!
3. Be careful when touching the exterior of an operating motor
- it may be hot enough to be painful or cause injury. It is
normal for modern motors to be hot when they operate at
rated load and voltage because modern motors are built
to operate at higher temperatures.
4. Do not insert any object into the motor.
5. Protect the power cable from coming in contact with sharp
objects.
6. Do not kink the power cable and never allow the cable to
come in contact with oil, grease, hot surfaces or chemicals.
7. Make certain that the power source conforms to the
requirements of your equipment.
8. Do not handle the pump with wet hands or while standing
in water because electrical shock could occur. Disconnect
the main power before handling the unit for ANY REASON.
9. The unit should run clockwise as viewed facing shaft end.
Counterclockwise rotation can result in damage to the
pump motor, property damage and/or personal injury.
10. Release all pressure within the system before servicing
any component.
11. The maximum liquid temperature is 180
o
F for Series 9700
centrifugal pumps.
12. Drain all liquids from the system before servicing any
component. Flush with water.
13. Secure the discharge lines before starting the pump. An
unsecured line may whip, causing personal injury and/or
property damage.
14. Hypro pumps are not designed to be used as clean water
pumps as dened in 10CFR Parts 429 and 431.
California Proposition 65 Warning -- This product and related accessories contain chemicals known to the State
of California to cause cancer, birth defects or other reproductive harm.