The integrated oating switch is disabled so that the pump can run in continuous mode:
MANUAL MODE:
1. Lift the front lever and place it
in position "MAN" (see Fig. 1).
2. To start the pump, insert the
plug in a 230 V current socket.
EN
Start-up (see g. 1 pag. 91)
CHAPTER 6
Use the pump for the applications listed on the nameplate.
WARNING
INSTRUCTIONS FOR A SAFE PUMP START
AUTOMATIC MODE
The power cable should have a minimum section equivalent to that of H05 RN-F. To be able to use the
pump outdoors, it is necessary to use cable with a length of 10 m. The plug and connections should be
protected by water splashes.
The maximum suction level of 3 mm can be reached in manual mode only. If the level of the uid to
suck is below 20 mm, maximum suction, up to a residual level of 3 meters, can be attained more
quickly by starting and topping the pump 2 or 3 times.
Pentair DPC pumps have an integrated oating switch. When the water reaches the start-up level, the
integrated oating switch automatically starts the pump.
When the water falls below the stop level, the integrated oating switch stops the pump.
1. Lower the front lever and
place it in location "AUT" (see
Fig. 1).
2. Place the pump in a stable
and straight position so that
the integrated oating switch
is able to move freely.
3. To start the pump, insert the
plug in a 230 V current socket.