12
ENGLISH
and then attach the compression piece
and the cutting rotor again.
3. Block the cutting rotor and tighten
again with the hexagon socket screw
(tightening torque 8 Nm).
4. Check the freedom of movement of
the cutting rotor and the cutting clear-
ance again (max. 0.2 mm).
If the cutting clearance is still too big,
a further adjusting washer must be re-
moved. Steps 1-4 must be repeated.
Cleaning
Worn impellers can have sharp
edges.
To clean the impeller and the spiral
housing first of all remove the com-
pression piece and the cutting rotor as
described above. Then unscrew the 4
hexagon socket screws and remove the
spiral housing.
The impeller and the spiral housing can
now be cleaned. After this fit the indi-
vidual components again and adjust the
cutting clearance.
To clean the pump chamber a flushing
pipe can be fitted as and when required.
Type I-M is screwed into place immedi-
ately in front of the flange of pump 08/2
M. With the MultiCut 20/2 M, the “Luft”
(Air) sealing screw is removed and the
Type 0 flushing pipe is screwed in.
ATTENTION! If the wrong screws are
unscrewed, the oil will run out of the oil
reservoir.
Tightening torque M
A
for A2 screw ma-
terials
for plastic screw Torx Plus® 25 IP 5x12
MA = 2,5 Nm
for M 6 M
A
= 8 Nm
for M 8 M
A
= 20 Nm
for M 10 M
A
= 40 Nm
for M 12 M
A
= 70 Nm
for M 16 M
A
= 160 Nm
WHAT TO DO IN THE
EVENT OF ANY
PROBLEMS
Pump does not work
Check mains current (do not use a
pin gauge)
Fuse faulty = may be too weak (please
refer to Electrical Connection)
Mains supply cable damaged = repair
to be carried out by manufacturer
only
Pump runs but does not pump
Empty pressure pipe or hose to allow
the non-return valve to open and let
the air escape from the spiral hous-
ing.
Cutting system blocked
Check the cutting system and read-
just or replace as necessary.
Impeller blocked
Clean spiral housing and impeller.
Decreased pumping performance
The impeller is worn out = replace it
Wrong direction of rotation = change
2 phases of the power supply