EasyManua.ls Logo

Pentair MASTERTEMP MT200HD - Operation of Ignition Module; Temperature Setting; Maximum Temperature Set Point

Pentair MASTERTEMP MT200HD
160 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MASTERTEMP
Pool and Spa Heater Installation and User’s Guide P/N 475106 Rev. D 1/2016
6 | Section
Diagnostic LED
1 Flash - Air Flow Fault
2 Flashes - Flame No Call For Heat
3 Flashes - Ignition Lockout
Flame Current
Check Point
Figure 5.
SAFETY CONTROLS, (continued)
OPERATION OF IGNITION MODULE
The Ignition Module, (see Figure 5), is microprocessor based and
operates on 24VAC supplied by the transformer. The control utilizes
a microprocessor to continually and safely monitor, analyze, and
control the proper operation of the gas flame holder. The module
with the presence of the flame sensor, using flame rectification,
allows the heater to operate.
TEMPERATURE SETTING
The heater comes factory set at 25.6° C (78° F). for the pool mode and 37.8° C (100° F). for the spa mode. Using the up
and down arrows, you can set the pool/spa thermostats to a minimum temperature of 18.3° C (65° F.), or a maximum of
40° C (104° F). If you desire to heat only one body of water, the thermostat is capable of an off mode. As an example, if
you only wish to heat the spa and not the pool, simply depress and hold the pool down arrow, and the thermostat will
lower its setting to 18.3° C (65° F.) then go to an off mode. See below to change the heaters factory set temperature
settings.
MAXIMUM TEMPERATURE SET POINT
1. Unbolt and remove the door panels (see Figure 6).
2. Access the control panel board on the underside of the top cover.
Locate the yellow button on the corner of the control board.
3. Push the Max. Temp. Set Point button on the back of the
control board (see Figure 7).
The following sequence should happen:
1. The unit turns on and the POOL ON light will
turn on.
2. Press the
TEMP or TEMP button (on TOP of the
control panel) to set maximum pool temperature.
3. Wait up to 30 seconds; the POOL ON light will turn off
and the SPA ON
light will turn on. To override the time
delay, push the Max. Temp. Set Point
button again.
4. Press the
TEMP or TEMP button on the control
panel and set maximum spa temperature to 40°C
(104° F) or less.
5. Wait up to 30 seconds; the SPA ON light will turn off
and the unit will shut down. To override the time delay,
push the Max. Temp. Set Point
button again.
6. Reinstall the access door panels.
Door
Acces
s
Panel
Top Panel
Door
Access Panel
Figure 6.
S1
SET
MAX
S1
SET
MA
X
Figure 7.
1. Operations