ELECTRIC CONNECTION  STARTUP
CHAPTER 4
The pumps used in ponds, small lakes, fountains or similar installations or close to them should have a cut-out switch.
Contact a specialised electrician.
• Use the handle provided to transport
or lift the pump
• To use the pump in permanent
installations with rigid pipes, to
install a check valve to avoid the fluid
being re-circulated once the pump
is stopped
• The installation of a quick closing
fitting in a convenient position
facilitates cleaning and maintenance
operations
• The power cable should have a
minimum section equivalent to that
of H05 RN-F and a length not less
than 10m
• The plug and connections should be
protected by water splashes. Before
using the pump, always inspect it
visually (especially power cable and
plug)
• Do not use the pump if it is damaged
• If the pump is damaged, have
it inspected by the specialised
assistance service only
• Make sure that electric connections
are protected from inundation
• Protect the plug and the power cable
from heat, oil or sharp edges
Verify that the voltage and frequency of the electropump shown on the nameplate correspond to those
available on the mains.
WARNING
The installer must make sure that the electric system is grounded in accordance with the law in force.
The power cable must be replaced by qualified personnel only.
Make sure that the electric system has a high-sensitivity circuit breaker ∆=30 mA (DIN VDE 0100T739).
DANGER - ELECTRIC SHOCK RISK
DANGER - ELECTRIC SHOCK RISK
DANGER - ELECTRIC SHOCK RISK
• The dimensions of the collection
container should reduce to the
minimum the number of starts per
hour (max 30)
• To use the pump for temporary
applications, install a flexible pipe
and connect it to the pump using a
pipe holder
• To immerse the pump, use a rope and
fix it to the handle
• The automatic DP - DPV model
is equipped with a pre-set float
switch (See fig.1) please increase or
decrease the free piece of float switch
cable by making it sliding through the
proper seat on the handlebar, when
modifyng the rating of float switch
• There can be particular requirements
for pumps used in or next to pools,
garden ponds or similar places
Verify that the floating switch stops the pump as soon as the minimum level is reached.
Assicurarsi che il galleggiante non sia ostacolato in alcun modo.
WARNING
WARNING
INSTRUCTIONS FOR A SAFE PUMP START