4 SHURFLO WATER BOOST MODULAR FILTRATION SYSTEM INSTALLATION AND OPERATION GUIDE
PERFORMANCE DATA
Important Notice: Read this performance data and compare the capabilities of this system with your actual water treatment
needs. It is recommended that, before installing a water treatment system, you have your water supply tested to determine
your actual water treatment needs.
This system has been tested according to NSF/ANSI 42 for the reduction of the substances listed below. The concentration
of the indicated substances in the water entering the system was reduced to the concentrations less than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSI 42.
MOD30422/MOD122TO5
Substance
Influent Challenge
Concentration
Maximum Permissible
Product Water
Concentration Reduction Requirements Average Reduction
Standard 42 Aesthetic Effects
Chlorine 2.0 mg/L ± 10% ≥50% 97.4%
Particulate Class III
particles 0.5 to <1 m
at least 10,000
particles/mL
≥85% 99.8%
Flow Rate = 7.5 gpm (26.87 lpm) Capacity = 60,000 Gallons (227,124.7 liters)
MOD30422/MOD122PLUS
Substance
Influent Challenge
Concentration
Maximum Permissible
Product Water
Concentration Reduction Requirements Average Reduction
Standard 42 Aesthetic Effects
Chloramines
1
3.0 mg/L ± 10% 0.5 mg/L 97.81%
Chlorine 2.0 mg/L ± 10% ≥50% 97.81%
1
As monochloramine (measured as Cl
2
/L) Flow Rate = 5.1 gpm (19.3 lpm) Capacity = 6,450 Gallons (24,415.9 liters)
TEST CONDITIONS OPERATING REQUIREMENTS
Inlet Pressure = 60 ± 3 psig (4.13 bar) Pressure = 20-125 psi (1.4-8.62 bar)
pH = 7.5 ± 0.5 Temperature = 40-100° F (4.4-37.8° C)
Temperature = 68 ± 5°F (20 ± 3°C)
Testing was performed under standard laboratory conditions, actual performance may vary.