SECTION 5. ELECTRICAL CONNECTION
The electrical motor must be wired by a professional accord-
ing to this installation instruction and all applicable local reg-
ulations.By introduction of the pump a motor security has to
be foreseen by the installation. The security has to be tuned
into the nominal power of the motor.
The supply voltage should be within ±5% of the rated
voltage,on the nameplate of the motor.
Single-phase motors should be connected at the two ter-
minals as indicated below. Single phase wiring diagram :
Make sure that you interrupt the power supply to the
cables when connecting the cables of the pump
Please remove lead wires from terminalsprior
to installation !
Please check the turning direction of three-phase motors
following each connection. If this does not correspond to
the arrow on the pump, two phase connections in the
junction box must be reversed. Every motor must be
permanently grounded.
Connections which do not conform to the above
mentioned safety instruction are not covered by the
warranty.
Section 6. Servicing
The pump is designed to operate for many years without
servicing. Always disconnect the power supply to the
pump before servicing. The replacement of the electrical
motor must be done by a professional.
Pentek
Capacitor
Supply
W1
U1
W2
Ground
Leroy-Somer
(Pentair)
1
2
3
4
5
6
N
L
7
Supply
Capacitor
Ground
Three phase motors
wired to main voltage
of 3x230 Volt require
a DELTA connection
3 x 230 V
W2
U2
U2
V1
V2
W1
Three phase motors
wired to main voltage
of 3x400 Volt require
a STAR connection
3 x 400 V
W2 U2 V2
U2 V1 W1
1
2
3
4
5
6
N
L
7
English
W2 U2 V2
U2 V1 W1
SECTION 7. TROUBLESHOOTING
Pump will not prime
1. No water in strainer pot
2. Strainer pot is not tight
3.DamagelidO-ring
4. Water level is below skimmer
5.Strainer basket or skimmer basket is clogged
6. Closed valve in piping system
7.Air leak in suction line
Motor does not turn
1.Power switch is o
2. Circuit breaker has tripped
3.Pump is o-mode of a timer controlled circuit
4. Motor terminal connections are incorrect
5.Motor shaft is locked
6. Impeller is locked by debris
Low ow/high lter pressure
1. Filter is dirty
2. Restriction in return line
Low ow/low lter pressure
1. Strainer basket or skimmer basket is clogged
2. Clogged impeller
3.Air leak in suction line
4. Restriction in suction line
5.Reverse rotation of motor (three phase only)
Noisy pump
1. Air leak in suction
2. Foreign matter in pump housing
3. Cavitation
An illustrated spare parts list can be found at:
www.pentairpooleurope.com
W2 U2 V2
U2 V1 W1
English
U1
U1