77420 - 43/107 -
16. [Adjustment] Position of J100
Required equipment: flashlight or equivalent
*Mirror must be at down position.
Cover the eyepiece with a hand or black tape.
Positioning the flashlight to the photo sensor as shown
in the figure right, and search the position where the
pattern of the photo sensor can be seen on the 1
st
mirror from
the mount ring side.
[Ref.] Attaching brighter lens is advisable to assist better visibility. (Ex.: FA 50mm f/1.4 Lens)
The photo sensor must be positioned at the AF frame and there is no inclination as shown in the figure.
[Adjust] Loosen the screw a little, move J100 to adjust whole position.
Tighten screw and ensure position is not changed.
After adjustment is completed, apply the Daia bond to J100 (4 places) as
shown in the figure.
ADJ.
Bond
J100
Bond
Flashlight
Sensor
1
st
Mirror
AF frame for spot metering(φ2.5
Photo sensor (J100)
Center position of sensor
Tolerance0.250.85mm