77420 - 65/107 -
5. [Adjustment] M100 adjustment (AF)
[Caution1] When T100 is replaced, this adjustment is required.
[Caution2] When replace M100 or adjusted M100 position, this adjustment is required.
[Caustion3] When replace 0-A101 or 0-B52 and adjusted mirror position, this adjustment is required.
*Some pictures and adjustment screen are using previous model but basic contents (usage / operation
message) are the same as K-r.
[Required equipment]
Programmed software for 77420 ---M100 adjustment (K-r SLR_Uni and K-r SLR_FI)
PC (Windows Xp (SP2), with USB port equipped) USB cable (I-USB17) AC adaptor kit
D-FA(FA) Macro 50mm F2.8 Light source (LV12) AF chart for 2m x2 kinds AF master lens for 2m
5-1. AF Uniformity and related adjustment.
[Required equipments]
D-FA(FA) Macro 50mm F2.8 Light source (LV12) Lens cap and ME finder cap
①Set the mode dial at [M] and Focus mode switch at [MF]
②Attach the lens to the camera and set focus ring at infinity.
③Set the camera at center of Light source window.
④Click [Kr SLR_Uni.exe] in [K-r SLR_Uni] folder to start up software.
(Adjustment screen will be displayed)
⑤Click [Execute] button to start adjustment.
⑥When [Lens cap] is displayed, put lens cap and finder cap to the camera. Turn OFF the Light source.
⑦Click [OK] to continue the adjustment.