77420 - 73/107 -
7. [Adjustment] SR adjustment II (Gain adjustment)
*Adjustment is basically the same as 76830 (K10D) and 76700(K100D).
[Caution1] When replaced T100, T640, T950or SR block, this adjustment is required.
[Caution2]SR adjustment I (Unit adjustment)should be completed before this adjustment.
[Caution3]Execute the adjustment on the stable table and do not give the vibration to the camera during the
adjustment.
[Caution4] The weight of the stage is more than 10kg, so pay attention the handling. Do not hold black stand
parts.
*Some pictures and adjustment screen are using previous model but basic contents (usage / operation
message) are the same as K-r.
[Required equipment]
Programmed software for 77420--- K-r_SR_Gain
SR gain adjustment set *(Controller, stage, speed meter)
Chart for SR gain adjustment (Attached in service manual for 76700)
Personal computer (Windows Xp (PS2) which equipped USB port)
DA 50-200mm lens USB cable Enough capacity of Battery
7-1. Setting the SR adjustment tools
Set the SR adjustment equipment on the desk (Desk must be stability and sturdy).
Set the chart 2m away from the camera stand.
Setting the stage, controller and speed meter as follow. (Turn the power of the controller OFF)
7-2.Preparation
Set the chart () 2.00m
from tripod screw part on the camera stand.
Lighting the chart evenly. Surface of chart should be approx. LV10-LV12.
Set the zooming position at 200mm and distance ring set at 2m and then fix each setting with tape.
(To avoid backlash, fix four positions by tap)
Attach lens to the camera
Set the camera to the following condition.
Mode dial: M
AF switch: MF
Stage
Controller
(Power off) Speed meter
Camera stand
Motor
AC100V
Knob
s
Chart (2m)