1Mbps is selected.
Beacon Interval
A
This option is for setting the time interval between each beacon. By default,
100ms is selected.
DTIM
A
This field allows you to set the frequency for the beacon to include a delivery
traffic indication message. The interval is measured in milliseconds. The
default value is set to 1 ms .
Slot Time
A
This field is for specifying the wait time before the Router transmits a packet.
By default, this field is set to 9 µs .
ACK Timeout
A
This field is for setting the wait time to receive an acknowledgement packet
before performing a retransmission. By default, this field is set to 48 µs .
Frame
Aggregation
A
This option allows you to enable frame aggregation to increase transmission
throughput.
Guard Interval
A
This setting allows choosing a short or long guard period interval for your
transmissions.
A
- Advanced feature, please click the button on the top right-hand corner to activate.