22
Flame Characteristics
Check for proper burner flame characteristics. Burner flames should be blue and stable with no yellow tips,
excessive noise, or lifting as shown in fig. 24. The following steps should be followed for correcting the
flame characteristics:
1. Turn the control knobs “OFF”. Close the Natural gas shut-off valve.
2. Allow the grill and burners to cool.
3. If the flame is yellow (not enough air), turn the adjustment screw found at the front of the burner
counterclockwise.
4. If the flame is noisy or lifts away from the burner (too much air), turn the adjustment screw
clockwise.
5. If these adjustments do not correct the problem, contact customer service at 1-877-323-5263.
Fig. 24
TROUBLESHOOTING
When to Look for Spiders
You should inspect the burners at least twice a year or immediately after any of the following conditions
occur:
1. The smell of gas in conjunction with burner flames appearing yellow.
2. The grill does not reach temperature.
3. The grill heats unevenly.
4. The burners make popping noises.
BEFORE CALLING FOR SERVICE
If the grill does not function properly, use the following checklist before contacting your dealer for service.
You may save yourself the cost of a service call.
WARNING
Spiders and insects can nest inside the burners of the grill and disrupt gas flow. This very
dangerous condition could cause a fire behind the valve panel, thereby damaging the grill and
making it unsafe for operation. Inspect the grill at least twice a year.