WHATTODOIF...
FuseInspectionandReplacement
Alltheelectricalcircuitshavefuses
toprotectthemfromashortcircuitor
overload.Ifsomethingelectricalon
yourchassisstopsworking,therst
thingyoushouldcheckforisablown
fuse.
1.TurnOFFalllightsandaccessories
andremovetheignitionkeyto
avoiddamagingtheelectrical
system.
2.Determinefromthechartonthe
fusepanelwhichfusecontrolsthat
component.
3.Removethatfuseandseeifitis
blown.
1Blown
Ifitisblown,replaceitwithafuseof
thesamerating.
Ifafuseofthesameratingisnot
available,afuseofalowerratingmay
betemporarilysubstituted.Youcan
alsouseafusefromacircuityoucan
dotemporarilywithout(forexamplean
accessorycircuitorradio).
CAUTION
Whenreplacingafailedcircuit
breaker,alwaysuseanapproved
circuitbreakerwithacurrentrat-
ingequaltoorlessthanthecircuit
breakerbeingreplaced.Onlyuse
theapprovedTypeIImodiedre-
setcircuitbreakers.NEVERuse
aTypeI(automaticreset)orType
III(manualreset)circuitbreaker.A
fusewithacurrentratingequaltoor
lessthanthecircuitbreakerbeing
replacedcanalsobeused.