Justierung
18
Fig. 1 - 13
1
3
2
0,2 - 0,3 mm
1.05.12 Target positioning sensor (only on the 939U)
Requirement
There should be a clearance of 0.2 0.3 mm between sensor 1 and control cam 3.
Adjust sensor 1 (screws 2) in accordance with the requirement.