EasyManua.ls Logo

Pfaff 3704-2/03 - Lifting Stroke of the Main and Differential Feed Dogs

Pfaff 3704-2/03
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Justierung
34
Fig. 1 - 29
1.05.28 Lifting stroke of the main and differential feed dogs
Adjust eccentric 1 (screws 2) in accordance with the requirement.
Eccentric 1 should not be axially displaced.
Requirement
With the stitch length set at "0" and the needle bar positioned at 0.25 after t.d.c. (hole 3),
the feed dogs should be at the top of their stroke.
2
1

Table of Contents