V4.1
WARNING! When the converter is turned OFF using a switch on the AUX terminals,
dangerous voltage may still be present on the input lines and elsewhere inside the
enclosure. Never open the enclosure or perform maintenance on the unit or
connected loads when the incoming power to the phase converter is ON, regardless
of the switch setting.
Table 27 Control Terminal Ratings and Descriptions
Terminal
Description
Rating
Comments
AUX1
Auxiliary Input 1
Dry contact type
Pullup Voltage
< 5 volts,
galvanically
isolated
Digital input. Commonly used for
ON/OFF control of output.
AUX2
Auxiliary Input 2
COM
Common
Common for AUX terminals.
AUX3
Auxiliary Input 3
Used for programming different
modes. See next section for details.
AUX4
Auxiliary Input 4
CAUTION! Electrostatic discharge (ESD) can damage electronic components.
Discharge ESD prior to touching the board or making connections. To discharge ESD,
touch your hand to unpainted metal on the enclosure.