MLR-352
MLR-352HSeries
MLR-352H
Please read the operating instructions carefully before using this product, and keep the operating
instructions for future use.
See page 65 for model number.
Operating Instructions
Versatile Environmental Test Chamber

Table of Contents

Questions and Answers

  • V
    Vanessa WalkerAug 9, 2025
    What to do if the alarm is activated on Phcbi Laboratory Equipment?
    • L
      Laurie PriceAug 9, 2025
      If the alarm is activated on your Phcbi Laboratory Equipment, it could be due to several reasons. First, the chamber temperature might be exceeding the set high or low limit. Check the chamber temperature settings and the high/low limit temperature alarm settings. Also, putting a lot of heat load into the chamber at once can trigger the alarm; the alarm should stop when the chamber temperature decreases. Ensure there isn't an excessive heat source inside. Electromagnetic waves from nearby appliances may also cause this issue, so keep the unit away from such appliances.
  • M
    Martin ColonAug 20, 2025
    Why is my Phcbi Laboratory Equipment not working even when switched on?
    • A
      agriffinAug 20, 2025
      If your Phcbi Laboratory Equipment isn't operating when switched on, the issue could stem from the unit not being properly connected to the power supply, or the power source may not have sufficient capacity. Ensure the unit is correctly connected and that the power supply is adequate. Alternatively, there might be a power failure, a blown fuse, or an activated circuit breaker. Check the power status, the fuse, and the circuit breaker to resolve this.
  • K
    Katrina ReidAug 29, 2025
    How to fix a temperature program that isn't working on Phcbi MLR-352H?
    • J
      Julie ConradAug 29, 2025
      If the temperature isn't changing according to the program you've set on your Phcbi Laboratory Equipment, it might be because the programmed temperature variation exceeds the unit's pull-up/pull-down performance capabilities. Try setting a program that takes the unit's performance into consideration. Also, incorrect high/low limit temperature alarm settings can cause this issue; double-check and correct these settings. Finally, electromagnetic waves from nearby appliances may interfere with the unit's operation, so keep it away from such appliances.

Summary

PRECAUTIONS FOR SAFE OPERATION

Safety Symbols and Labels

Explains warning and caution symbols and labels on the unit for user safety.

Installation Site Safety

Details safe installation locations and environmental conditions to avoid hazards.

Operational Safety Measures

Covers safety measures during operation, maintenance, and handling of the unit.

Electrical and Usage Safety

Advises on electrical connections, usage limitations, and corrosive substance storage.

CHAMBER COMPONENTS

INSTALLATION SITE

Environment and Location Guidelines

Lists essential conditions for selecting an installation site to ensure proper operation.

Installation Environment Cautions

Provides specific advice on temperature, water supply, and frost prevention for installation.

INSTALLATION

Unit Setup Procedures

Outlines steps for removing packaging, leveling, fixing, and grounding the unit.

BEFORE COMMENCING OPERATION

TOP SCREEN OPERATION

CONTROL PANEL FUNCTIONS

Programming and Editing Cycles

Guide to creating and editing programmed operating cycles.

Program Execution and Management

Instructions for starting, joining, skipping, and stopping programmed operations.

VARIOUS SETTINGS

HUMIDITY CONTROL

ROUTINE MAINTENANCE

ALARMS & SAFETY FUNCTIONS

Alarm Conditions and Responses

Describes temperature, humidity, and other alarms with their causes and indications.

TROUBLESHOOTING

SPECIFICATIONS

Phcbi MLR-352H Series Specifications