System Monitor PSM 2
REV 1A – Software V3 Page 4
1.3 CE Conformity
philippi elektrische systeme gmbh certifies herewith, that the System Monitor PSM2
fulfils the requirements of the European Regulation:
2004/108/EG “Electromagnetic compatibility”
The compatibility of the device is certified by the CE-sign.
2 Content
1x System Monitor PSM2
1x Pluggable 3-pole terminal for the connection of the power supply
2x M12 terminators (male + female)
1x M12 T-cable
This instruction manual
3 Technical data
Nominal voltage DC 8-32 V
Power consumption 100 mA @ 12 V operating at 100% illumination.
5 mA @ 12 V at stand-by mode (illumination 0%).
Dimensions: 105 x 105 x 40 mm
Cut out: 88 x 88 mm
Software Versions
FEB 2017 VERSION 1 First Version
MRZ 2017 VERSION 2 Second version with temperature display
JUN 2017 VERSION 3 Third version with integration of PSS / EM-box V3
4. Installation
4.1 Necessary equipment
Following parts are needed for the installation of the PSM2:
- terminator female and male (content of the PSM package)
- M12-T-cable for the connection of the monitor to the PBUS
(content of the PSM package)
- For each further PBUS component you need a further M12-connection cable.