System Monitor PSM 2
REV 1A – Software V3 Page 11
Off: For this device the alert notification is turned off and no alarm will be
displayed /reported.
Message: For this device the alert notification will be displayed in form of a
report
Message For this device the alert notification will be shown on the display as a
+ Buzzer report and simultaneously an acoustic signal occurs and the display
is flashing.
6.5 System time
The PSM2 is equipped with a battery-backed real-time clock, which makes it possible
to have a punctual time stamp in the protocoling. It also makes it easier to assign the
alerts temporal.
The time and date can be adjusted through the keypad.
Should the clock have deviations they can be
adjusted through the Setup System Time.
Thereby 1 Hz comply with a deviation of 2,6
seconds per day.
If the monitor starts with the date set to 1970
the time must be adjusted accordingly. If the
installed header is empty, the battery must be
removed and replaced. Therefore, the rear lid
must be removed and the header has to be
shoved out of the holder and be replaced with
a new battery (CR2032-3V).
6.7 Consumer (digital switch)
Here the user can assign the consumer relays to the display buttons.
This assignment has to be carried out individually for each PSM2 monitor, because
each PSM2 monitor can be configurated differently.