PHILIPS Respironics BiPAP A40 User Manual

PHILIPS Respironics BiPAP A40
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
This guide contains abstracted information from the User Manual; please refer
to the latest version for complete information regarding the BiPAP A40 device.
How to reach us
www.philips.com/healthcare
healthcare@philips.com
Asia
+49 7031 463 2254
Europe, Middle East, Africa
+49 7031 463 2254
Latin America
+55 11 2125 0744
North America
+1 425 487 7000
800 285 5585 (toll free, US only
)
Philips Respironics
1010 Murry Ridge Lane
Murrysville, PA 15668 USA
Philips Respironics Asia Pacific
+65 6882 5282
Philips Respironics Australia
+61 (2) 9947 0440
1300 766 488 (toll free,
Australia only)
Philips Respironics China
+86 400 828 6665
+86 800 828 6665
Philips Respironics Deutschland
+49 8152 93 06 0
Philips Respironics France
+33 2 51 89 36 00
Philips Respironics Italy
+39 039 203 1
Philips Respironics Sweden
+46 8 120 45 900
Philips Respironics Switzerland
+41 6 27 45 17 50
Philips Respironics
United Kingdom
+44 800 1300 845
www.philips.com/respironics
© 2016 Koninklijke Philips N.V. All rights are reserved.
BiPAP A40 is registered trademark of Philips.
Philips Healthcare reserves the right to make changes in specifications and/or to
discontinue any product at any time without notice or obligation and will not be
liable for any consequences resulting from the use of this publication.
Broudy RP 4/24/16 MCI 4107145 PN 1098001
Question and Answer IconNeed help?

Do you have a question about the PHILIPS Respironics BiPAP A40 and is the answer not in the manual?

PHILIPS Respironics BiPAP A40 Specifications

General IconGeneral
BrandPHILIPS Respironics
ModelBiPAP A40
RampYes
HumidificationIntegrated heated humidifier
DisplayColor LCD
Data StorageSD card
Voltage100 - 240 VAC, 50/60 Hz
Power SourceAC power
Device TypeBi-Level PAP
Therapy ModesCPAP
Pressure Range4-40 cm H2O
Ramp Time0-45 minutes
ConnectivityBluetooth
Operating Sound Level26 dBA

Summary

Battery module

Undocking the battery module or humidifier

Procedure for detaching the battery module or humidifier from the therapy device.

Connection to oximetry

Guidelines for ventilation

Initial settings

Defines initial settings for IPAP, EPAP, BPM, Rise time, and Ti based on patient conditions.

AVAPS rate

Describes how AVAPS rate setting depends on patient needs and clinical condition.

Ventilation Set-up Tables

Inspiratory time conversion table

Table to set inspiratory time for controlled breaths based on breath rate and I/E ratio.

Target tidal volume conversion table

Table to set target tidal volume based on ideal weight and target volume per kg.

Getting started

Device navigation

Overview of the device display screen and button functions for navigation.

How to start therapy

Steps to connect power, switch on the device, and initiate therapy.

Therapy operation

How to stop therapy

Instructions on stopping therapy, including standby and power off options.

How to unlock the device

Procedure to unlock the device to access setup or options.

Main screen overview

Mode of ventilation and indicators

Explanation of ventilation modes, pressure bar graph, and monitored values on the main screen.

Symbols and icons explained

Guide to interpreting various symbols and icons displayed on the device screen.

Menus and settings

Settings and alarms menu

Details of configurable settings and alarms available in the device's menu.

Additional settings and alarms

Configuration options for tubing, alarms, and low minute ventilation.

AVAPS-AE mode settings

Specific settings and ranges for the AVAPS-AE ventilation mode.

Menu: Options

Options parameters and navigation

Explanation of available options parameters like menu access, language, and screen saver.