EasyManua.ls Logo

Philips EP 5400 Series - Level 2: Electrovavle (EV1) Testing

Philips EP 5400 Series
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...

Sequence of
actions by user
Reaction of the appliance
PASS FAIL Cause of failure Solution
EV
Press and release
K to toggle the
EV.
If it was closed,
then will be
open.
L White ON in UI panel +
BoxK White in Display +
BoxT Green in Display +
BoxT Green in Display
It’s possible to hear the “click”.
The “click” is no
audible. The EV
remain closed
Wiring of the EV not
connected
Check the wiring
Wiring of the EV
damaged (open)
Change Main
Board
EV damaged Change the EV
The drive of the EV in
the Main is damaged
Change Main
Board
Press and release
K to toggle the
EV.
If it was open,
then will be
closed.
L OFF in UI panel +
BoxK OFF in Display +
BoxT Green in Display +
BoxT Green in Display
It’s possible to hear the “click”.
The “click” is no
audible. The EV
remain open
EV damaged Change the EV
The drive of the
motor in the Main is
damaged
Change Main
Board
Test mode

Related product manuals