Removal of the Coee and Water spout
. To remove the front panel start at the lower snap (). Push to the left and on top of it, then the cover opens at the
front side and you can put a nger (nail) in between. Then push on the upper snap nock ().
. Pull down the coee spout, then remove the pipe.
. Take out the  screws
. Unsnap the click (as shown in picture) and pull the front case cover to remove it (some force is needed).
. Remove the two screws to release the water spout.
Removal of the Microswitch
. To remove the microswitch please take extra care, slowly pulling it out from its place, then remove the
connections.