4.4 TEST FREQUENCY TABLE
NOTE; The appropriate table of information should be programmed into the transceiver.
Frequency
Band
(MHz)
Channel
Number
Test Frequency
(MHz)
TX
Rx
OPTION DETAILS
Transmit
CTCSS
Selcall
EO 1 68.025 68.525 25
68 to 88
2
78.025
78.525
25
3
87.025
87.525
25
4
68.025
68.525
1
107.2Hz
5
78.025
78.525
1
107.2Hz
ENC test
6
87.025
87.525
1
107.2Hz
BO
1
132.025
132.525
25
132 to 156
2
140.025
140.525
25
3
155
.025
155.525
25
4
132,025
132.525
1
107.2Hz
5
140.025
140.525
1
107.2Hz
ENC test
6 155.025 155.525 1 107.2Hz
A9
1
146.025
146.525
25
146 to 174
2
160.025
160.525
25
3
173.025
173.525
25
4
146.025
146.525
1
107.2Hz
5
160.025
160.525
1
107.2Hz
ENC test
6 173.025 173.525 1 107.2Hz
Tm
1
400.025
400.525
25
400 to 440
2
420.025
425.525
25
3
439.025
439.525
25
4
400.025
400.525
1
107.2Hz
5
420.025
420.525
1
107.2Hz
6 439.025 439.525 1 107.2Hz
ENC test
ton
e
U0
1
440.025
440.525
25
440 to 470
2
455.025
455.525
25
3
469.025
469.525
25
4
440.025
440.525
1
107.2Hz
5
455.025
455.525
1
107.2Hz
6
469.025
469.525
1
107.2Hz
ENC test
Section 4 Page 2