EasyManua.ls Logo

Philips PRM80 Series - Section 2: Technical Specifications; General Specifications

Philips PRM80 Series
79 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SECTION 2 TECHNICAL SPECIFICATIONS
Unless otherwise stated, specifications apply for an ambient temperature of 25 Deg C and
13.8V supply.
2.1 GENERAL
Operation
Single- or two-frequency simplex.
Modulation
Frequency.
Supply Voltage
10.8V to 16.2V dc, negative earthed to chassis.
Frequency Bands
VHF UHF
E0 68 - 88 MHz Tm 400 - 440 MHz
B0 132 - 156 MHz U0 440 - 470 MHz
A9 146 - 174 MHz W 1 470 - 500 MHz
W4 500 - 520 MHz
Channel Spacing
VHF UHF
12.5 kHz 12.5 kHz
20 kHz 20 kHz
25/30 kHz 25 kHz
Frequency Stability
UHF & VHF (option) +/-5ppm -10 Deg C to +60 Deg C (better quality
crystal).
VHF
+/-10ppm -10 Deg C to +60 Deg C (standard
crystal).
VHF & UHF (USA) +/-5ppm -30 Deg C to +60 Deg C (extended temp
option).
UHF
+/-2.5ppm -10 Deg C to +60 Deg C (TCXO).
UHF +/-2.5ppm -30 Deg C to +60 Deg C (TCXO).
VHF +/-10ppm -30 Deg C to +60 Deg C (extended temp
option)
Section 2 Page 1

Table of Contents