Configure a TC Router to turn on Output 1 via SMS message
Step 1
Navigate to wireless network > SMS configuration
Enable SMS control, and enter a SMS password
• The password can contain up to 7 alphanumeric characters (e.g. abc1234)
Click Apply
Figure 6: Enable SMS control
Step 2
Navigate to I/O > Outputs
Select Remote Controlled by the drop-down menu
• Refer to the Appendix for information on the other output choices
Select “Autoreset” if you would like the output to turn off automatically after a period of time.
Click Apply