EasyManua.ls Logo

Phoenix R200 LGR - User Manual

Phoenix R200 LGR
9 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Owner’s Manual — Phoenix R200 LGR Dehumidifier
Installation, Operation & Service Instructions
1
www.UsePhoenix.com • sales@UsePhoenix.comToll-Free 1-800-533-7533
Read and Save These Instructions
The Phoenix R200 LGR Dehumidifier
Patented Bypass Technology - Increased performance over a
wide temperature range.
R-410A Refrigerant - The Phoenix R200 comes charged
with R-410A refrigerant.
Capacity - The Phoenix R200 removes 125 pints per day at
AHAM (80°F/60%RH).
Energy Efficiency - Draws only 8.3 amps and removes 5.2
pints/kWh.
Compact Design - Smaller, 20”x20”x33.5”, and only 105 lbs.
Motorized Impeller - 325 CFM; Faster drying and superior
static pressure for ducting.
More Grain Depression - Drier air from an LGR finishes jobs
quicker versus a conventional refrigerant dehumidifier.
Focused Airflow - Patent focused outlet directs air downward
across the wet surface.
Multiple Ducting Options - 12” intake, 10” exhaust.
Plastic Housing - Rugged roto-molded housing.
Solid State Controls - Easy to read and operate.
Protected Condensate Hose - Located under the top cover.
Quick connect, cannot catch or be damaged on obstructions.
Telescoping Handle - A heavy-duty retractable handle for ease
of transport and reduces space for storage and stacking.
Recessed 12” Wheels - Allows greater maneuverability on the
job site and efficient storage. Rolls over obstacles with ease.
Pleated Media Air Filter - A 12”x12”x1” MERV-11 filter is
standard.
Stacking/Nesting - Reduces space for ease of stacking and
storage.
Specifications subject to change without notice.
TS-391
09/13
4201 Lien Rd. • Madison, WI 53704
Phoenix R200
Part No. 4027000
Patent 7,246,503
7,281,389
7,540,166
The Phoenix R200 is a compact, energy efficient LGR
dehumidifier that removes 125 pints per day (AHAM) while
drawing only 8.3 amps of electricity. The R200 outperforms
larger competitive dehumidifiers by removing more water,
providing larger grain depression and consuming less power.
The proven LGR design is surrounded by a durable roto-
molded high impact plastic to create a dehumidifier that is
smaller and lighter than competitive units.
In addition to the performance benefits and compact size,
the R200 has patented bypass technology, increased
airflow, multiple ducting options, and a pleated media
filter. The R200 is the latest member of the Phoenix line of
LGR dehumidifiers; the most effective and versatile drying
devices made.
BYPASS
Patented
Question and Answer IconNeed help?

Do you have a question about the Phoenix R200 LGR and is the answer not in the manual?

Summary

The Phoenix R200 LGR Dehumidifier

Safety and Specifications

1 Safety Certifications

Conforms to ANSI/UL 474 and CSA C22.2 No.92 standards.

2 Specifications

Technical details including part number, power, water removal, blower, refrigerant, range, filters, and dimensions.

Operation

3.1 Transporting

Guidance on moving the unit using its handle and wheels, and storage considerations.

3.2 Electrical Requirements

Details on power connection, circuit requirements, and extension cord usage for wet areas.

3.3 Condensate Removal

Information on the internal pump, hose length, and overflow protection for water removal.

3.4 Ducting

Instructions for attaching exhaust and intake ducting to the unit for airflow management.

3.5 Defrost Cycle

Explanation of how the unit manages frost on the evaporator coil and the defrost indicator light.

3.6 Power Button

How to turn the dehumidifier on and off using the power button and the display.

3.7 Purge Button

Manual operation of the condensate pump using the purge button for reservoir emptying.

3.8 Hour Meter

Understanding the digital hour meter for tracking total and job hours of operation.

3.9 Hours Button

How to display hour meter readings when the unit is off and reset job hours.

3.10 Defrost Light

Indicates when the unit is in a defrost cycle and the compressor is off.

3.11 Bypass Control

Adjusting the bypass cover for optimal performance at different ambient temperatures.

Maintenance and Service

4.1 Air Filter

Importance of checking and maintaining the MERV-11 air filter for unit efficiency and longevity.

4.2 Storage

Procedures for preparing the unit for storage, including draining and cleaning to prevent damage.

5.1 Technical Description

Overview of the refrigeration system's function in removing heat and moisture.

5.2 Troubleshooting

Common issues and solutions for dehumidifier operation problems, such as no dehumidification or compressor issues.

5.3 Air Mover

Details on the motorized impeller, its function, and replacement procedures.

5.4 Thermistor

Location and replacement steps for the defrost thermistor.

5.5 Condensate Pump

Instructions for replacing the internal condensate pump and its associated parts.

5.6 Float Safety Switch

How the float safety switch operates and its replacement procedure.

Options and Diagrams

6 Options & Accessories

List of available accessories for the Phoenix R200 dehumidifier.

7 Wiring Diagram

Schematic showing electrical connections and component layout.

Service Parts

Phoenix R200 Dehumidifier Limited Warranty

Who Is Covered

Defines warranty coverage for the original end-user.

End-User Responsibilities

Outlines requirements for warranty service, care, and exclusions.

Limitation and Exclusions

Details warranty limitations, exclusions, and liability disclaimers.

Legal Rights

Explains specific legal rights granted by the warranty.

Phoenix R200 LGR Specifications

General IconGeneral
ModelPhoenix R200 LGR
RefrigerantR410A
Voltage115V
Frequency60 Hz
Water Removal (Saturation)200 pints per day
Tank CapacityN/A (Continuous Drain)