Table of Contents
Introduction ...............................................................1
1. Safety Certifications ..............................................2
2. Specifications .......................................................2
3. Operation ............................................................2
3.1 Transporting ...................................................2
3.2 Electrical Requirements ..................................2
3.3 Condensate Removal ......................................3
3.4 Ducting ..........................................................3
3.5 Defrost Cycle .................................................3
3.6 Power Button .................................................3
3.7 Purge Button ..................................................3
3.8 Hour Meter ....................................................3
3.9 Hours Button .................................................3
3.10 Defrost Light ................................................4
3.11 Bypass Control .............................................4
4. Maintenance ........................................................4
4.1 Air Filter ......................................................... 4
4.2 Storage .........................................................4
5. Service ................................................................4
5.1 Technical Description ......................................4
5.2 Troubleshooting ..............................................5
5.3 Air Mover .......................................................6
5.4 Thermistor .....................................................6
5.5 Condensate Pump ..........................................6
5.6 Float Safety Switch .........................................6
6. Options & Accessories ..........................................7
7. Wiring Diagram ....................................................7
8. Service Parts .......................................................8
9. Warranty ..............................................................9
1 Safety Certifications
The Phoenix R200 conforms to standards ANSI/UL 474
and CSA C22.2 No.92.
2 Specifications
Part No. 4027000
Power 8.3 amps, 120 VAC, Grounded
Water 125 pints/day @ AHAM (80°F, 60%)
Removal 26 gal/day maximum @ saturation
Blower 325 CFM without external ducting
300 CFM @ .15 IWG external static
Refrigerant 1 lb, 10 oz. R-410A
Charge
Operating 33°F to 110°F
Range
Filters: 12” x 12” x 1” Pleated Media MERV-11
Duct Intake – 12” Flex-Duct
Options Outlet – 10” Lay-Flat
Warranty Five years;
1st year 100% of Parts and Labor
2nd-5th year 100% of sealed refrigeration
system parts.
Dimensions
Unit Shipping
Width 20” 21”
Height 33.5” 35.25”
Depth 20” 21”
Weight 105 lbs 115 lbs
Patent - 7,246,503
7,281,389
7,540,166
3 Operation
Place dehumidifier inside structure,
place condensate hose into a drain, or
a large water tight container, and turn
on. To decrease drying times, make sure
all windows and doors are closed to the
outside and seal off the affected wet
areas from unaffected areas.
Optimum performance will be observed
between the temperatures of 70°F and
95°F.
3.1 Transporting
The Phoenix R200 features a high impact roto-molded
housing with 12” recessed wheels and a telescoping
handle. The rugged roto-molded housing protects the
dehumidifier from damage. The 12” wheels provide
greater maneuverability and roll over obstacles with ease.
The telescoping handle and recessed wheels create a
Read the operation and maintenance instructions
carefully before using this unit. Proper adherence to
these instructions is essential to obtain maximum
benefit from your Phoenix R200 dehumidifier.
• It is designed to be used INDOORS ONLY.
• If used in a wet area, plug it into a GROUND FAULT
INTERRUPTER.
• DO NOT use the Phoenix R200 as a bench or table.
• It must always be used in the upright position.
Figure 1: Stacked
Phoenix R200