10
5. Measurement Capability
5.1 Real-time Basic Electrical Parameters
SPM90 can measure basic electrical parameters including voltage, current
and power.
Real-time reading
Measurement range
Current
Shunt 100A
0 ~ 100A
Shunt 150A
0 ~ 150A
Shunt 200A
0 ~ 200A
Shunt 300A
0 ~ 300A
Shunt 400A
0 ~ 400A
Voltage
2~1000V
Power
2W ~ 400kW
5.1.1 Voltage
Voltage measurement range of SPM90 is 2~1000V. Users should be noted
this to prevent saturation of internal measurement circuit, which may cause
inaccurate measurement.
Note: If “U ERR V” is displayed when voltage is over 50V, it means
that wires on port 1 and 2 are reversely connected.