PNOZ X4
Operating Manual PNOZ X4
19894-EN-07
13
Legend
} S1/S2: E-STOP/safety gate switch
} S3: Reset button
} : Switch operated
} : Gate open
} : Gate closed
Operation
NOTICE
Check each safety function
after initial commissioning and after each change of the machine/
plant
for SIL CL 3/PL e at least 1x per month, for SIL CL 2/PL d at least 1x
per year
Follow the instructions below:
Activate the safety function and check whether all the used safety
contacts open.
Prepare for operation again and start the unit. All the used safety
contacts must be closed again.
The safety functions may only be checked by qualified personnel.
Status indicators
LEDs indicate the status and errors during operation:
LED on
POWER
Supply voltage is present.
CH.1
Safety contacts of channel 1 are closed.
CH.2
Safety contacts of channel 2 are closed.

Other manuals for Pilz PNOZ X4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pilz PNOZ X4 and is the answer not in the manual?

Pilz PNOZ X4 Specifications

General IconGeneral
Supply Voltage24 V DC
Contacts3 N/O, 1 N/C
Width45 mm
Depth121 mm
MountingDIN rail
PL according to EN ISO 13849-1PL e
Category according to EN 954-14
SIL according to IEC 61508SIL 3
Max. switching current6 A
Protection classIP20
Operating Temperature-10 °C to +55 °C
Stop Category0
SIL CL according to EN IEC 62061SIL CL 3
Number of safe inputs2
Number of safe outputs3
Operating temperature range-10 °C to +55 °C