PNOZ X4
Operating Manual PNOZ X4
19894-EN-07
5
INFORMATION
This gives advice on applications and provides information on special fea-
tures.
Safety
Intended use
The safety relay PNOZ X4 provides a safety-related interruption of a safety circuit.
The safety relay meets the requirements of EN60947-5-1, EN60204-1 and VDE0113‑1
and may be used in applications with
} E-STOP pushbuttons
} Safety gates
} Light grids and safety switches with detection of shorts across contacts
The following is deemed improper use in particular:
} Any component, technical or electrical modification to the product
} Use of the product outside the areas described in this manual
} Use of the product outside the technical details (see Technical details [ 15]).
NOTICE
EMC-compliant electrical installation
The product is designed for use in an industrial environment. The product
may cause interference if installed in other environments. If installed in other
environments, measures should be taken to comply with the applicable
standards and directives for the respective installation site with regard to in-
terference.
Safety regulations
Safety assessment
Before using a unit it is necessary to perform a safety assessment in accordance with the
Machinery Directive.
Functional safety is guaranteed for the product as a single component. However, this does
not guarantee the functional safety of the overall plant/machine. In order to achieve the re-
quired safety level for the overall plant/machine, define the safety requirements for the
plant/machine and then define how these must be implemented from a technical and organ-
isational standpoint.

Other manuals for Pilz PNOZ X4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pilz PNOZ X4 and is the answer not in the manual?

Pilz PNOZ X4 Specifications

General IconGeneral
Supply Voltage24 V DC
Contacts3 N/O, 1 N/C
Width45 mm
Depth121 mm
MountingDIN rail
PL according to EN ISO 13849-1PL e
Category according to EN 954-14
SIL according to IEC 61508SIL 3
Max. switching current6 A
Protection classIP20
Operating Temperature-10 °C to +55 °C
Stop Category0
SIL CL according to EN IEC 62061SIL CL 3
Number of safe inputs2
Number of safe outputs3
Operating temperature range-10 °C to +55 °C