Installation and alignment
Operating Manual PSEN opII3H Series
1003503-EN-08
| 33
14,5
6
6,3
19
Bore holes in the installation surface (two M6 screw
boreholes per flexible bracket) for mounting the flexible
brackets for the transmitter and receiver.
[1]
Fix the transmitter and receiver and their flexible
brackets in place on the installation surface.
For each bracket, use two mounting screws with wash-
ers [1] included in delivery [ 12]. If necessary,
mounting screws with deviating lengths can be used.
Transmitters and receivers can be shifted vertically
and horizontally.
Screws are only tightened to the final torque during
alignment.
Ensure that the transmitters and receivers are properly
installed in a suitable place.
Ensure that the transmitters and receivers are posi-
tioned at the same height and parallel to one another.