Do you have a question about the Pilz PSEN ml b 1.1 and is the answer not in the manual?
Number of beams | 1 |
---|---|
Supply voltage | 24 V DC |
Protection type | IP67 |
Number of contacts | 2 |
Rated voltage | 24 V DC |
Housing material | Plastic |
Connection type | M12 connector |
Type of light | Infrared light |
Operating temperature | -10°C to +55°C |
Manual validity for PSEN ml b 1.1/2.1/2.2 from Version 2.0.
Document is for instruction; read and understand before installation and commissioning.
Explains DANGER, WARNING, CAUTION, and NOTICE symbols used in the manual.
Use for interlocking and guard locking of swing/sliding gates; operation modes.
Safety assessment, additional documents, qualified personnel, warranty, disposal.
Warning about potential contamination and risk of injury due to loss of safety function.
Lists approved combinations of safety switches and actuators for PSEN ml b 1.1 and 2.X.
Lists key features like safe guard locking, transponder technology, diagnostics, auxiliary release, coding.
Explains the interlocking and guard locking system and safety outputs.
Details how guard locking is activated/deactivated via inputs S31/S41.
Describes the optional Safety Device Diagnostics for sensor monitoring and configuration.
Explains the function of the auxiliary release for opening the guard locking.
Details the escape release accessory for manual release from the danger zone.
Notes on connector handling and maximum cable length with SDD.
Details the 8-pin M12 connector pinout and cable colours.
Covers EMC requirements, UL requirements, and protective separation for voltages.
Properties required for evaluation devices, OSSD signals, and SDD usage.
Requirements for PL e (Cat. 4) and PL d (Cat. 3) applications.
Illustrates a single connection for PL d (Cat. 2) applications.
Shows connection examples with PNOZmulti and Safety Device Diagnostics.
Automatic detection of actuators for PSEN ml b 1.1.
Teaching in new actuators for PSEN ml b 2.1, including procedures.
Automatic detection of actuators for PSEN ml b 2.2.
Guidelines on reducing defeat possibilities, reachability, stability, shock/vibration, mounting surfaces.
Covers installation on sliding gates and swing gates.
Mounting positions, holding forces, and tapped holes for safety switch installation.
Methods for installing the actuator without or with a mounting bracket.
Important information on escape release installation and functional restrictions.
Procedure for tightening actuator screw connections after alignment.
Describes LED status indicators and switch status for normal operation.
Details error codes, LED status, and remedy measures for various fault conditions.
Checks for seals, damage, security, offsets, wiring, and dirt.
Procedures for testing actuator detection, guard locking activation, and safety outputs.
Checks for detectability, reachability, and function of the escape release.
Provides dimensional drawings and measurements for the safety switch.
Shows dimensional drawings and measurements for different actuator types.
Certifications, operating modes, design, coding, and electrical data for the product.
Details specifications for OSSD safety outputs, signal outputs, and switching current.
Lists test pulse duration, switch-on delay, actuator times, and risk time.
Specifies storage temperature, operating temperature range, humidity, and EMC.
Covers holding forces, offsets, speeds, dimensions, weight, and cable length.
Describes classes and specific values for solenoid input interfaces.
Describes classes and specific values for safe 1-pole HL output interfaces.
Provides explanations for SIL CL, PFHD, and TM values.
FCC and IC compliance information for USA/Canada.
Specifications for mounting brackets, including holding force and weight.
Specifications for mounting brackets with handle units.
Details release force, service life, and weight for specific escape release models.
Lists product types, features, and order numbers for safety gate systems and components.
Lists product types, features, and order numbers for installation accessories.
A guide for commissioning, recommissioning, and regular testing of the PSEN ml b/ba/s/sa.