8.5.3 Installation stationary escape release
1. Remove the security screw [1] using a Torx T10 screwdriver T10.
2. Screw the adapter disk of the escape release with the two hexagon sockets M3x8[3]
on the safety switch with 1,2 - 1,5 Nm (see diagram). The pin of the adapter disk [2]
must be at the place where the security screw of the auxiliary release [1] used to be.
[1]
[2]
[3]
Legend
[1] Security screw of the auxiliary release
[2] Pin in the adapter disk
[3] Hexagon sockets M3x8
3. Screw the escape release with the four raised head screws M3x12 to the adapter disk
with 1,2 - 1,5 Nm (see diagram).
} The button of the escape release pin can be removed for the installation (e.g. when the
escape release pin is to be run through a wall). Once the installation of the escape re-
lease is complete, the button of the escape release pin must be secured again with a me-
dium-strength threadlocker and hand-tightened
} To bridge larger distances the escape release pin can be extended by a max. of 25mm
two times (see Order reference: Accessories [ 75]).