EasyManua.ls Logo

Pilz PSEN opII3H Series - Malfunction

Pilz PSEN opII3H Series
90 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation
Operating Manual PSEN opII3H Series
1003503-EN-08
| 49
Meaning
green
green
green
Safety light curtain in operation
Transmitter sends B-coded
red red
An error has occurred.
Perform a safety light curtain
restart [ 49].
red
red
green
Overtemperature; OSSD in the OFF
state
1. Ensure that the ambient temperature
corresponds to the information in the
Technical details [ 55].
2. Perform a safety light curtain
restart [ 49].
red
red
green
Undervoltage; OSSD in the OFF state
1. Ensure that the supply voltage cor-
responds to the information in the
Technical details [ 55].
2. Perform a safety light curtain
restart [ 49].
9.3 Safety light grid restart
a Disconnect the voltage supply from the safety light curtain, then reconnect the safety
light curtain back to the voltage supply. The safety light curtains start
automatically [ 17].
9.4 Malfunction
WARNING!
Loss of safety function due to a malfunction of the safety light curtain
A safety light curtain malfunction may lead to serious injury or death.
If there is a safety light curtain malfunction, immediately discontinue opera-
tion of the system components whose danger zone the grid secures.