FORCE Series Installation Guide
28 PIMA Electronic Systems
Set event and restore codes for the following events:
1)
Panic
and
Fire
alarms,
Technician On-site
, Invalid Code, Test.
2)
Tampers:
Tamper 1-2
and
Peripherals
’ Alarm and Restore codes.
7.1.3 Custom Zones Reports
System Configuration
CMS & Communications
Monitoring Stations
Custom Zones Reports
Set the ContactID (alarm and restore) codes, and SIA’s alarm and restore codes for the custom
zones. Custom zones are based on modified zone types that allow alarm reporting with any
ContactID or SIA code (other than the original zone type - Burglary, Panic, etc.).
Below is a list of more frequently used ContactID and SIA events, which can be used with the
custom zones.
7.2 PIMA Cloud
System Configuration
CMS & Communications
PIMA Cloud
Network
(Ethernet)
Cellular Data
1. Select the communication path of the cloud.
2. Do not change the default URL (force.pimalink.com) or IP address
(13000) for the selected path.
3. Set the Port to 0 for the other path.
Select if the cloud will be the main communication path. When cleared, this
path will backup the main path.
Only select one main path, or the communication
with the cloud will be unstable!
Do not change the default cloud URL, or the cloud service will be
unavailable. Consult with PIMA first when it is required.