RXN-406 Keypad for CAPTAIN-i - User Guide
7
S
YSTEM
F
UNCTIONS
IMPORTANT!
The
[
symbol indicates information that you must enter.
To arm/disarm Partition #1:
[User Code
To arm/disarm Partition #2:
[User Code
To arm
/disarm
the entire Alarm System:
[
Any User Code that
belongs to either partitions OR
[
Short Code.
NOTE:
A user can arm/disarm only partitions allocated to him/her by the technician
(partitions #1, #2, or both).
All keypads connected to the system share the same display, even if they are
allocated to different partitions.
IMPORTANT!
Entering the Master Code + when one of the partitions is armed will
arm the other partition as well.
Entering the Master Code + when both partitions are armed will disarm
the entire system.
To arm the alarm system in HOME mode:
Press and hold
[
any User Code OR Short Code.
NOTES:
Since CAPTAIN-i has only one HOME state, pressing either key 7 or 4 makes
no difference.
When the FAULT LED is blinking and there is no other indication LED blinking
simultaneously, the fault is ‘Clock not set’.
To disarm the alarm system in HOME mode:
[
any User Code
To bypass/re-arm a bypassed alarm zone:
[
Primary Code
[
zone number
[