PDP-427CMX
74
1234
1234
C
D
F
A
B
E
[QSU]: To acquire data on the audio status
[QSI]: Response format
[QCI]: Response format
Order Data Contents Size Remarks
1 STX 1Byte 02hex
2 Command echo back 3Byte QSU (fixed)
3 Main volume 3Byte 000 - 042
4 Audio mute state 1Byte 0: OFF 1: ON
5 INPUT1 sub volume 3Byte 000 - 020
6 INPUT2 sub volume 3Byte 000 - 020
7 INPUT3 sub volume 3Byte 000 - 020
8 INPUT4 sub volume 3Byte 000 - 020
9 INPUT5 sub volume 3Byte 000 - 020
10 Check sum 2Byte
11 ETX 1Byte 03hex
Order Data Contents Value
Length
(BYTE)
1 STX 1 0x02
2 Echo back 3 "QCI"
3 Time information 2 Time (24 hours system)
2 Minute
2 Seconds
4 Dummy data 8 All "∗"
5 Days 1 Days (refer to the following table)
6 Check sum 2 (CS)
7 ETX 1 0x03
[QCI]: Days
Days
(response)
Days
Sunday"1"
"2" Monday
Tuesday"3"
"4"
Wednesday
"5" Thursday
"6" Friday
"7" Saturday
14: Detection of existence of H
N No H
YH detected
18 to 20: Each protection
operation status
0 Setting OFF
1 Setting ON (waiting)
2 Setting ON (during operation)
22: Transition of brightness by
protection operation
0 Upper limit state for brightness
1 Brightness being reduced
2 Lower limit state for brightness
3 Brightness being increased
Data Arrangement
Data Length
Output Example
ECO 3 Byte QSI
1 Type of drive sequence 3 Byte 60V
2 Standard/nonstandard 1 Byte S
3 Type of ABL/WB tables 2 Byte T1
4 Total value of PCN 4 Byte 0256
5 Total value of PRH 4 Byte 0256
6 Total value of PGH 4 Byte 0256
7 Total value of PBH 4 Byte 0256
8 Total value of PBR 4 Byte 0512
9 Total value of PRL 4 Byte 0512
10 Total value of PGL 4 Byte 0512
11 Total value of PBL 4 Byte 0512
12 Total value of ABL 3 Byte 128
13 Detection of V frequency 4 Byte 6002
14 Detection of existence of H 1 Byte
Y
15 Reserved 3 Byte
***
16 Obtained APL data 4 Byte
1023
17 Number of SUS pulses 4 Byte 0457
18 Result of detection of still picture 1 Byte 1
19 Result of detection of cracking in the panel 1 Byte 1
20 Result of detection for scanning protection 1 Byte 1
21 Result of detection for external protection 1 Byte 1
22 Transition of protection operation 1 Byte 0
23 Reserved 4 Byte ****
CS 2 Byte 27
If the data for the current time are fewer than two digits (0-9,) the higher-order
digit will be padded with a zero.
If the data for the current minute are fewer than two digits (0-9,) the
higher-order digit will be padded with a zero.
If the data for the current second are fewer than two digits (0-9,) the
higher-order digit will be padded with a zero.