Data Arrangement
Data
Length
Output Example
ECO 3 byte QS3
1 SERIAL 15 byte - - - - - - - - - - - - - - -
2 HOUR METER 8 byte 00000000
3 TOTAL HR METER 8 byte 00000000
4 PON COUNTER 8 byte 00000000
5 TEMP1 acquisition (Temperature value) 5 byte +23.5 (*1)
6 TEMP0 acquisition (Temperature value) 5 byte +28.7 (*1)
7 MAX-TEMP1 acquisition (Temperature value) 5 byte +78.3 (*1)
8 Reserved 4 byte
∗∗∗∗
CS 2 byte 94
Command
Format
Effective Operation
Modes
Function Remarks
[QS3] All operations
To acquire data on operations of the panel
Return data: 3 (ECO) + 58 (DATA) + 2 (CS) = 63 Byte
The command QS3 is for acquiring data on operational information of the panel.
Note
(*1) : Centigrade scale