FAN CONT1
TEMP2
FAN_NG1 (H act)
V+3_3V_UCOM
TEMP2
FAN_12V
Drive
Circuit
PULL_U
PULL_U
SENSOR
FAN ON1
Fan and temperature sensor
Circuit configuration
MAIN Assy
SENSOR Assy
TANSHI Assy
DIGITAL Assy
IF_UCOM
FAN
1
V+3_3V_UCOM
TEMP1
SENSOR
MAIN_UCOM
MODULE_
UCOM
PULL_D
Specifications for port monitoring
Port Name SD/PD Indication Active
FAN_NG1 FAN1
Shutdown occurs when
the signal is "H."
1 S ∗ 3 times
TEMP2 High temperature at
MTB
Shutdown occurs if any
values equal to or
greater than minimum to
require a shutdown are
detected.
1 S ∗ 3 times
Monitoring conditions
RST4 = H and FAN_ON1 = H
(Monitoring starts 3 sec after the
above conditions are established.)
Operation
If FAN_NG1 (for details on detection logic, see "File of
fan-control specifications") is detected (established) under the
monitoring conditions, a shutdown process starts. A specific
LED flash pattern (blue LED, 10 times) starts.
The next PON operation is valid, and the flag is cleared upon
the next power-on.
RST4 = H
(Monitoring starts 1 sec after the
above conditions are established.)
If any values equal to or greater than minimum to
require a shutdown are detected (established) under
the monitoring conditions, a warning indication will be
displayed for 30 sec, after which a shutdown process
starts. A specific LED flash pattern (blue LED, 11 times)
starts.
The next PON operation is valid, and the flag is cleared
upon the next power-on.
TMP_NG
High temperature in
the drive circuits
Low temperature in
the drive circuits
Shutdown occurs if any
values equal to or
greater than minimum to
require a shutdown are
detected.
200 mS ∗ 5 times
(average)
Digital video RST2 = H
If any values equal to or greater than minimum to
require a shutdown is detected (established) under the
monitoring conditions, those changes in status will be
transmitted to the main microcomputer via the UART.
Upon receiving the data, a warning indication will be
displayed for 30 sec, after which a shutdown process
starts. The main microcomputer orders a specific LED
flash pattern (blue LED, 4 times).
The next PON operation is valid, and the flag is cleared
upon the next power-on.
If any values equal to or greater than minimum to
require a shutdown is detected (established) under the
monitoring conditions, those changes in status will be
transmitted to the main microcomputer via the UART.
Upon receiving the data, the main microcomputer
orders a specific LED flash pattern (blue LED, 4 times).
The next PON operation is valid, and the flag is cleared
upon the next power-on.